Sunricher SR-ZG9060A-GS
Smart combustible gas sensor
Services and characteristics
The following HomeKit Services and Characteristics are exposed by the Sunricher SR-ZG9060A-GS
- Battery
- Battery Level
- Charging State
- Status Low Battery
Exposes
This is the information provided by Zigbee2MQTT for this device:
[
{
"name": "gas_alarm_1",
"label": "Gas alarm 1",
"access": 1,
"type": "binary",
"property": "gas_alarm_1",
"description": "Indicates whether the device detected gas (alarm_1)",
"value_on": true,
"value_off": false
},
{
"name": "gas_alarm_2",
"label": "Gas alarm 2",
"access": 1,
"type": "binary",
"property": "gas_alarm_2",
"description": "Indicates whether the device detected gas (alarm_2)",
"value_on": true,
"value_off": false
},
{
"name": "tamper",
"label": "Tamper",
"access": 1,
"type": "binary",
"property": "tamper",
"description": "Indicates whether the device is tampered",
"category": "diagnostic",
"value_on": true,
"value_off": false
},
{
"name": "battery_low",
"label": "Battery low",
"access": 1,
"type": "binary",
"property": "battery_low",
"description": "Indicates whether the battery of the device is almost empty",
"category": "diagnostic",
"value_on": true,
"value_off": false
},
{
"name": "warning",
"label": "Warning",
"access": 2,
"type": "composite",
"property": "warning",
"features": [
{
"name": "mode",
"label": "Mode",
"access": 2,
"type": "enum",
"property": "mode",
"description": "Mode of the warning (sound effect)",
"values": [
"stop",
"burglar",
"fire",
"emergency",
"police_panic",
"fire_panic",
"emergency_panic"
]
},
{
"name": "level",
"label": "Level",
"access": 2,
"type": "enum",
"property": "level",
"description": "Sound level",
"values": [
"low",
"medium",
"high",
"very_high"
]
},
{
"name": "strobe_level",
"label": "Strobe level",
"access": 2,
"type": "enum",
"property": "strobe_level",
"description": "Intensity of the strobe",
"values": [
"low",
"medium",
"high",
"very_high"
]
},
{
"name": "strobe",
"label": "Strobe",
"access": 2,
"type": "binary",
"property": "strobe",
"description": "Turn on/off the strobe (light) during warning",
"value_on": true,
"value_off": false
},
{
"name": "strobe_duty_cycle",
"label": "Strobe duty cycle",
"access": 2,
"type": "numeric",
"property": "strobe_duty_cycle",
"description": "Length of the flash cycle",
"value_max": 10,
"value_min": 0
},
{
"name": "duration",
"label": "Duration",
"access": 2,
"type": "numeric",
"property": "duration",
"description": "Duration in seconds of the alarm",
"unit": "s"
}
]
}
]